Pull-Out Test | Semi-Destructive Test

πŸ“˜ What is the Pull-Out Test?

The Pull-Out Test is a semi-destructive test in civil engineering used to assess the in-situ compressive strength of concrete or the bond strength between reinforcement and concrete.

There are two major applications:

  1. Concrete Strength Estimation
  2. Anchorage/Bond Strength Testing (for rebars, anchors, or post-installed bolts)

🎯 Objectives:

  • Determine in-place compressive strength of concrete.
  • Evaluate bond strength between steel and concrete.
  • Assess anchor performance for safety-critical applications.
  • Validate quality of concrete in structural elements like slabs, columns, beams, footings, etc.

🧰 Apparatus Required:

  • Pull-out test device with hydraulic jack or actuator
  • Dial gauge or load cell to measure force/load
  • Embedded or installed pull-out insert / rebar / anchor
  • Reaction frame or bearing plate
  • Support tripod or fixing system

πŸ› οΈ Test Procedure (General Overview):

A. Concrete Strength Pull-Out Test (LOK Test or CAPO Test):

  1. A metal insert is cast into the concrete during pouring.
  2. After curing, a pulling force is applied perpendicular to the concrete surface.
  3. The force required to dislodge the insert is recorded.
  4. This force is correlated with compressive strength using calibration curves.

B. Rebar or Anchor Pull-Out Test:

  1. Expose the rebar or install an anchor into the cured concrete.
  2. Connect the test setup to apply axial tension.
  3. Increase load steadily until:
    • Slip occurs
    • Pull-out occurs
    • Failure of anchor/concrete
  4. Record the maximum load at failure.

πŸ“Š Results & Interpretation:

Parameter Measured Typical Outcome
Pull-out load (kN) Indicates the force at failure/slip
Slip vs. load graph Assesses ductility and bond behavior
Failure mode Bond failure, rebar pull-out, concrete breakout
Equivalent compressive strength (for concrete inserts) Estimated using calibration

βœ… Advantages:

  • Reliable estimation of in-situ strength
  • Assesses actual performance of anchors and reinforcement
  • Helps in quality control and structural assessment

⚠️ Limitations:

  • Semi-destructive (may damage small part of concrete)
  • Requires calibration curves
  • Not suitable for lightweight or low-strength concrete
  • Needs careful alignment and reaction setup

πŸ“Œ Standards / Guidelines:

  • ASTM C900: Standard Test Method for Pullout Strength of Hardened Concrete
  • IS 2770 (Part 1): Indian Standard for Bond Strength of Reinforcement
  • EN 12504-3: Testing concrete in structures β€” Pull-out testing

πŸ—οΈ Applications:

  • Concrete core strength validation
  • Anchor bolt testing (e.g., faΓ§ade fixing, MEP supports)
  • Rebar anchorage pull-out tests
  • Post-installed systems verification

Leave a Reply